Change #57 · Add Superconductor Materials Lab: the equipment and stock of a small lab that makes and tests candidate superconductors. AI-assisted, from maker and seller pages checked on 2026-10-08. Batch catalog-create-superconductor-lab-2026-10-08; reviewed 2026-10-08. New pages only. accepted

by sd · 2026-10-08 19:19 · 105 nodes

New: Weighing Paper weighing-paper

  • Created Weighing Paper (part): "Holds each powder charge on the balance pan and lets it slide into the mortar without loss. Smooth low-nitrogen cellulose or glassine squares, 4 × 4 in (100 × 100 mm)."

New: Micro Spatulas micro-spatulas

  • Created Micro Spatulas (part): "Transfers powder between bottle, weighing paper, mortar and die. Stainless steel, about 150 mm long, with a spoon end and a flat end, one spatula per toxic precursor."

New: Agate Mortar and Pestle agate-mortar-and-pestle

  • Created Agate Mortar and Pestle (part): "Grinds and mixes precursor powders by hand and regrinds fired pellets between firings. Natural agate with a polished bowl, about 100 mm outer diameter for batches of a few grams, plus a 50 mm set for sub-gram samples."

New: Planetary Ball Mill planetary-ball-mill

  • Created Planetary Ball Mill (part): "Mills precursor batches more uniformly than hand grinding and mechanically alloys intermetallic powders. Benchtop mill with two to four stations for 50 to 100 mL jars, variable speed, a timer with reversing and a supply voltage that matches the room."

New: Milling Jars milling-jars

  • Created Milling Jars (part): "Holds the powder and grinding balls while the planetary mill runs. Agate or yttria-stabilized zirconia, 50 to 100 mL, with lid and gasket, sized for the mill's clamps and bought in matched pairs so the mill stays balanced."

New: Milling Media milling-media

  • Created Milling Media (part): "Mixes the powder and reduces its particle size inside the jar while the planetary mill runs. Same material as the jar, in mixed diameters of about 3, 5 and 10 mm, one set per jar."

New: Test Sieves test-sieves

  • Created Test Sieves (part): "Removes agglomerates and sets an upper particle size before pressing or powder X-ray diffraction. 3 in (76 mm) stainless steel frame and mesh certified to ASTM E11, one No. 200 (75 µm) and one No. 325 (45 µm) sieve, with a matching pan and cover."

New: Hydraulic Pellet Press hydraulic-pellet-press

  • Created Hydraulic Pellet Press (part): "Presses ground powder in a die into pellets for firing and for resistance and susceptibility measurements. Manual press rated 12 to 15 metric tons with a pressure gauge, a safety shield and enough opening height for the die with its plungers."

New: Pellet Die Sets pellet-die-sets

  • Created Pellet Die Sets (part): "Shapes the powder into a pellet of fixed diameter under the press. Hardened tool steel at HRC 60 or above with polished pressing faces, in 10 mm and 13 mm (or 12.7 mm) bore, or tungsten carbide for hard or abrasive powders."

New: Low-Speed Diamond Saw low-speed-diamond-saw

  • Created Low-Speed Diamond Saw (part): "Cuts rectangular bars from sintered pellets for four-probe resistance measurements with little chipping or heating. Gravity-fed saw for 4 to 5 in (100 to 127 mm) blades with variable speed up to 300 to 600 rpm, a micrometer cross-feed and a vise or chuck for small pellets."

New: Diamond Wafering Blade diamond-wafering-blade

  • Created Diamond Wafering Blade (part): "Cuts the sintered pellet with a thin diamond-edged rim when mounted on the low-speed saw. 4 in (102 mm) diameter, 0.3 to 0.35 mm thick, 0.5 in arbor, in a grade the maker lists for ceramics and other brittle materials."

New: Mounting Wax mounting-wax

  • Created Mounting Wax (part): "Holds a pellet on the saw's mounting block during cutting and releases it when reheated. Thermoplastic wax or adhesive stick that melts on a hot plate at roughly 75 to 135 °C and dissolves in acetone."

New: Saw Cutting Fluid saw-cutting-fluid

  • Created Saw Cutting Fluid (part): "Cools and lubricates the blade while a sintered pellet is cut into bars. Oil-based or otherwise water-free fluid, because YBCO and many other candidate phases degrade in water."

New: Silicon Carbide Abrasive Paper silicon-carbide-abrasive-paper

  • Created Silicon Carbide Abrasive Paper (part): "Flattens pellet faces, trims bars to size and removes the reacted surface layer before electrical contacts are applied. Waterproof silicon carbide sheets or 8 in discs, plain or adhesive backed, in 240, 600 and 1200 grit, used dry or with alcohol when the sample reacts with water."

New: Digital Caliper digital-caliper

  • Created Digital Caliper (part): "Measures pellet and bar dimensions, needed to convert resistance to resistivity and to calculate geometric density. 0 to 150 mm range, 0.01 mm resolution and ±0.02 mm accuracy."

New: Powder Preparation and Shaping superconductor-materials-lab-powder

  • Created Powder Preparation and Shaping (assembly): "Precursor powders are weighed on the analytical balance, ground in an agate mortar or the planetary mill and pressed into pellets in a die under the hydraulic press. After firing, the diamond saw and silicon carbide paper shape pellets into flat bars, and the caliper gives the dimensions for resistivity."
  • Added Analytical Balance × 1
  • Added weighing-paper × 2
  • Added micro-spatulas × 2
  • Added agate-mortar-and-pestle × 2
  • Added planetary-ball-mill × 1
  • Added milling-jars × 2
  • Added milling-media × 2
  • Added test-sieves × 1
  • Added hydraulic-pellet-press × 1
  • Added pellet-die-sets × 2
  • Added low-speed-diamond-saw × 1
  • Added diamond-wafering-blade × 2
  • Added mounting-wax × 1
  • Added saw-cutting-fluid × 1
  • Added silicon-carbide-abrasive-paper × 3
  • Added digital-caliper × 1

New: Tube Furnace tube-furnace

  • Created Tube Furnace (part): "Fires samples in flowing oxygen or argon, or under rough vacuum, inside a sealed work tube. Heated length of 150 to 300 mm with a uniform zone longer than the boat, a 50 mm work tube and a rating matched to the tube (1100 °C quartz, 1400 to 1500 °C alumina)."

New: Furnace Work Tube furnace-work-tube

  • Created Furnace Work Tube (part): "Holds the sample and the gas atmosphere inside the tube furnace and is replaced when it cracks or devitrifies. Outer diameter and length matched to the furnace and flanges, in fused quartz for runs up to about 1100 °C or alumina of at least 99% purity above that."

New: Vacuum Sealing Flange Set vacuum-sealing-flange-set

  • Created Vacuum Sealing Flange Set (part): "Seals both ends of the work tube and carries the gas inlet, gas outlet, vacuum port and pressure gauge. Check whether the furnace includes a set before buying a stainless steel pair sized to the tube, with silicone O-rings, needle valves and preferably a KF25 pump port."

New: Alumina Crucibles and Boats alumina-crucibles-and-boats

  • Created Alumina Crucibles and Boats (part): "Holds powder or pellets during firing, with boats for the tube furnace and crucibles for the box furnace. Dense high-purity alumina in 5 to 50 mL sizes, with boats narrower than the work tube bore and lids for charges with volatile components."

New: Crucible Tongs crucible-tongs

  • Created Crucible Tongs (part): "Moves hot crucibles and boats in and out of the furnace. Steel tongs at least 280 mm long and a second pair of 450 to 500 mm that reaches the back of a box furnace."

New: Thermocouple Probe and Reader thermocouple-probe-and-reader

  • Created Thermocouple Probe and Reader (part): "Measures the temperature along the furnace hot zone to check the controller reading and find the uniform region. Sheathed type K probe (type S above about 1200 °C) long enough to reach the tube center, with a handheld reader that resolves 1 °C or better."

New: Two-Stage Gas Regulator two-stage-gas-regulator

  • Created Two-Stage Gas Regulator (part): "Reduces cylinder pressure to a steady low delivery pressure for the furnace gas line or the torch. CGA inlet for the gas (540 oxygen, 580 argon, 350 hydrogen, 510 propane), delivery range of 0 to 15 or 0 to 50 psig, and oxygen-clean construction for oxygen service."

New: Gas Flow Meter gas-flow-meter

  • Created Gas Flow Meter (part): "Sets and displays the gas flow through the work tube during a run. Range of about 10 to 500 mL/min with a needle valve, either a float meter calibrated for one gas with correction factors for others or a mass flow controller."

New: Gas Tubing and Compression Fittings gas-tubing-and-compression-fittings

  • Created Gas Tubing and Compression Fittings (part): "Carries gas from the regulators through the flow meter to the furnace flange and on to the bubbler. 1/4 in outer diameter stainless steel or copper tubing with matching two-ferrule compression fittings, and an oxygen line cleaned for oxygen service."

New: Oil Bubbler oil-bubbler

  • Created Oil Bubbler (part): "Vents the furnace exhaust through oil so room air cannot diffuse back into the tube and the gas flow is visible. Glass bubbler with hose connections of about 8 mm and a reservoir head or check valve that stops oil being drawn back toward the furnace."

New: Rotary Vane Vacuum Pump rotary-vane-vacuum-pump

  • Created Rotary Vane Vacuum Pump (part): "Evacuates the work tube before backfilling with gas and pumps down quartz ampoules before sealing. Two-stage oil-sealed pump of about 4 to 10 m³/h with an ultimate pressure of a few mTorr, a KF25 inlet and an exhaust mist filter."

New: Vacuum Gauge vacuum-gauge

  • Created Vacuum Gauge (part): "Reads the pressure in the tube or ampoule line to confirm pump-down and reveal leaks. Convection-enhanced Pirani gauge for 0.0001 to 1000 Torr with a KF16 or KF25 fitting and a display, calibrated for nitrogen so argon readings need the maker's correction."

New: Vacuum Valve and KF Fittings vacuum-valve-and-kf-fittings

  • Created Vacuum Valve and KF Fittings (part): "Connects the pump to the furnace flange or ampoule and isolates the pump so the tube can be backfilled with gas. KF25 manual angle valve, flexible bellows hose, clamps and centering rings, plus an O-ring compression coupling sized to the quartz ampoule tubing."

New: Fused Quartz Tubing fused-quartz-tubing

  • Created Fused Quartz Tubing (part): "Forms the sealed ampoules that hold air-sensitive or volatile reactions under vacuum or argon. Clear fused quartz of 10 to 16 mm outer diameter and 1 to 2 mm wall in 1219 mm (4 ft) lengths, with the outer diameter matched to the vacuum coupling."

New: Glassworking Torch glassworking-torch

  • Created Glassworking Torch (part): "Melts and collapses fused quartz tubing to seal ampoules while they are held under vacuum. Torch burning oxygen with hydrogen, propane or natural gas, tips sized for 10 to 16 mm quartz, flashback arrestors on both hoses and welding-shade eyewear."

New: Fuel Gas Cylinder fuel-gas-cylinder

  • Created Fuel Gas Cylinder (part): "Supplies the hydrogen or propane that the glassworking torch burns with oxygen to seal quartz ampoules. Hydrogen (CGA 350) for a hotter, soot-free flame or propane (CGA 510) at lower cost, in a small cylinder usually leased from a local distributor, with its own regulator."

New: Arc Melter arc-melter

  • Created Arc Melter (part): "Melts metal pieces together under argon on a water-cooled copper hearth to make intermetallic buttons. Non-consumable tungsten electrode, water-cooled copper hearth for charges of 5 to 20 g, pump-down and argon backfill, and a recirculating chiller."

New: Furnaces, Gas and Vacuum superconductor-materials-lab-furnace

  • Created Furnaces, Gas and Vacuum (assembly): "A box furnace fires pellets and powders in air, and a tube furnace with regulators, a flow meter and a rotary vane pump fires them in flowing oxygen or argon after pump-down. An arc melter and quartz ampoules sealed with a torch make intermetallics, which an oxide-only program can skip."
  • Added Muffle Furnace × 1
  • Added tube-furnace × 1
  • Added furnace-work-tube × 2
  • Added vacuum-sealing-flange-set × 1
  • Added alumina-crucibles-and-boats × 20
  • Added crucible-tongs × 2
  • Added thermocouple-probe-and-reader × 1
  • Added two-stage-gas-regulator × 4
  • Added gas-flow-meter × 2
  • Added gas-tubing-and-compression-fittings × 1
  • Added oil-bubbler × 1
  • Added rotary-vane-vacuum-pump × 1
  • Added vacuum-gauge × 1
  • Added vacuum-valve-and-kf-fittings × 1
  • Added fused-quartz-tubing × 10
  • Added glassworking-torch × 1
  • Added fuel-gas-cylinder × 1
  • Added arc-melter × 1

New: Liquid Nitrogen Storage Dewar liquid-nitrogen-storage-dewar

  • Created Liquid Nitrogen Storage Dewar (part): "Stores liquid nitrogen between deliveries and fills the benchtop flasks. A 25 to 35 L aluminum dewar with static evaporation near 0.2 L per day and a neck wide enough to pour from, such as the 64 mm neck of the LD25."

New: Open Benchtop Dewar Flask open-benchtop-dewar-flask

  • Created Open Benchtop Dewar Flask (part): "Holds 1 to 2 L of liquid nitrogen on the bench for dipping the probe and for the levitation check. A 1 to 2 L open-neck flask with an inner diameter and depth that take the dip probe, a loose lid and a carrying handle."

New: Nitrogen Dip Probe or Pour-Fill Cryostat nitrogen-dip-probe-or-pour-fill-cryostat

  • Created Nitrogen Dip Probe or Pour-Fill Cryostat (part): "Carries the sample, its four contacts and a thermometer into the nitrogen bath to record resistance from room temperature to 77 K. A lab-built probe has a thin-wall stainless tube, copper sample block, spring pins, eight or more leads and a vent hole, and a bought cryostat holds the sample in vacuum."

New: Closed-Cycle Cryostat closed-cycle-cryostat

  • Created Closed-Cycle Cryostat (part): "Cools the sample below 77 K without liquid helium to measure transitions between about 4 K and 77 K. A two-stage Gifford-McMahon cold head reaching 10 K or 4 K with the sample in vacuum, a feedthrough for eight or more leads and cooling water if the compressor needs it."

New: Cryogenic Temperature Controller cryogenic-temperature-controller

  • Created Cryogenic Temperature Controller (part): "Reads the cryogenic sensors and drives the stage heater to hold or ramp temperature during a measurement. Two or more inputs for diode and resistance sensors, a PID heater output of 25 W or more and a computer interface for logging."

New: Cryogenic Temperature Sensors cryogenic-temperature-sensors

  • Created Cryogenic Temperature Sensors (part): "Measures the temperature of the sample stage and of the cold head. A silicon diode on a standard curve covers 1.4 K to 500 K without individual calibration, and a Pt100 platinum sensor suits work above about 30 K."

New: Precision Current Source precision-current-source

  • Created Precision Current Source (part): "Supplies a stable, reversible current through the outer two contacts of the four-probe sample. Output settable from about 1 µA to 100 mA with a compliance limit and computer-controlled reversal, and delta mode with a Keithley 2182A requires a 6220 or 6221."

New: Nanovoltmeter nanovoltmeter

  • Created Nanovoltmeter (part): "Measures the voltage across the inner two contacts, which falls to the noise floor when the sample superconducts. Nanovolt sensitivity, noise of a few tens of nanovolts peak to peak, two channels and triggering from the current source for current reversal."

New: Lock-In Amplifier lock-in-amplifier

  • Created Lock-In Amplifier (part): "Reads the pickup-coil voltage for AC susceptibility and measures AC four-probe resistance at low current. A frequency range covering 10 Hz to 100 kHz, input noise of a few nV per root Hz, a sine output to drive the primary coil and a computer interface."

New: AC Susceptibility Coil Set ac-susceptibility-coil-set

  • Created AC Susceptibility Coil Set (part): "Applies a small AC field and senses the sample's susceptibility, which turns diamagnetic at the transition, on two series-opposed pickup coils. Wound in the lab from 36 to 40 AWG enameled copper wire on a nonmetallic former sized to the probe, with pickup coils matched in turns and wound in opposite sense."

New: Gaussmeter with Hall Probe gaussmeter-with-hall-probe

  • Created Gaussmeter with Hall Probe (part): "Measures the field of the levitation magnets and of the susceptibility coil so that fields reported with a result are known. DC and AC field reading with a transverse or universal Hall probe, a range to at least 20 kG and 0.1 G resolution."

New: Bench Digital Multimeter bench-digital-multimeter

  • Created Bench Digital Multimeter (part): "Checks contact resistance and continuity before cooldown and reads a Pt100 thermometer by four-wire resistance. 6.5 digits with four-wire resistance and a USB, LAN or GPIB interface."

New: GPIB to USB Interface gpib-to-usb-interface

  • Created GPIB to USB Interface (part): "Connects instruments without USB or Ethernet, such as the nanovoltmeter, to the data acquisition computer over GPIB. An IEEE 488.2 controller with drivers for the computer's operating system and a VISA library so that Python or LabVIEW can address each instrument."

New: Silver Paint, Silver Epoxy and Indium silver-paint-silver-epoxy-and-indium

  • Created Silver Paint, Silver Epoxy and Indium (part): "Makes the four electrical contacts between fine wire and the sample as painted or cured silver joints or pressed indium pads. Air-drying silver paint for quick contacts, two-part silver epoxy for cured contacts and 99.99% indium foil or wire for pressed contacts and thermal joints."

New: Cryogenic Lead Wire and Fine Contact Wire cryogenic-lead-wire-and-fine-contact-wire

  • Created Cryogenic Lead Wire and Fine Contact Wire (part): "Carries signals down the probe with little heat leak and joins the sample contacts to the stage pads. 32 or 36 AWG insulated phosphor bronze for the probe leads and 25 µm gold or 40 AWG copper for the sample contacts."

New: Cryogenic Varnish, Grease and Polyimide Tape cryogenic-varnish-grease-and-polyimide-tape

  • Created Cryogenic Varnish, Grease and Polyimide Tape (part): "Anchors leads and sensors with varnish, joins the sample thermally to the stage with grease and insulates pads with tape. GE 7031 type varnish, Apiezon N grease in a 25 g tube and 1 mil polyimide tape with silicone adhesive in 6 to 25 mm widths."

New: SQUID Magnetometer or PPMS (Facility Access) squid-magnetometer-or-ppms-facility-access

  • Created SQUID Magnetometer or PPMS (Facility Access) (part): "Measures DC magnetization and shielding fraction, or resistance in fields of several tesla, to confirm a transition seen on the bench. Sold by quotation at a cost beyond a small lab budget, so small labs usually buy measurement time on one at a university facility."

New: Cryogenics and Measurement superconductor-materials-lab-measurement

  • Created Cryogenics and Measurement (assembly): "Cools a sample to 77 K on a dip probe, or lower in a closed-cycle cryostat, and measures four-probe resistance, AC susceptibility and magnet levitation. A current source and nanovoltmeter carry the resistance measurement, and a lock-in amplifier with a wound coil set carries the susceptibility."
  • Added liquid-nitrogen-storage-dewar × 1
  • Added open-benchtop-dewar-flask × 2
  • Added nitrogen-dip-probe-or-pour-fill-cryostat × 1
  • Added closed-cycle-cryostat × 1
  • Added cryogenic-temperature-controller × 1
  • Added cryogenic-temperature-sensors × 3
  • Added precision-current-source × 1
  • Added nanovoltmeter × 1
  • Added lock-in-amplifier × 1
  • Added ac-susceptibility-coil-set × 1
  • Added gaussmeter-with-hall-probe × 1
  • Added Neodymium Magnet × 10
  • Added bench-digital-multimeter × 1
  • Added gpib-to-usb-interface × 1
  • Added silver-paint-silver-epoxy-and-indium × 1
  • Added cryogenic-lead-wire-and-fine-contact-wire × 1
  • Added cryogenic-varnish-grease-and-polyimide-tape × 1
  • Added squid-magnetometer-or-ppms-facility-access × 1

New: Zero-Background Sample Holders zero-background-sample-holders

  • Created Zero-Background Sample Holders (part): "Holds a few milligrams of powder in the diffractometer without adding substrate peaks or an amorphous hump to the pattern. Single-crystal silicon cut off-axis, with no peaks from 20 to 120 degrees 2-theta under Cu K-alpha, sized for the diffractometer's holder, flat or with a shallow cavity."

New: Phase Identification and Rietveld Software phase-identification-and-rietveld-software

  • Created Phase Identification and Rietveld Software (part): "Matches a measured pattern against reference patterns to name the phases and refines lattice parameters and phase fractions by the Rietveld method. Must read the diffractometer's data format and the chosen reference database, which for the free programs is CIF files from COD."

New: Reference Pattern Database reference-pattern-database

  • Created Reference Pattern Database (part): "Supplies the reference patterns and crystal structures that a measured diffraction pattern is matched against to name the phases. Needs inorganic phases in a format the analysis software reads, CIF for the free databases or a licensed install for the ICDD Powder Diffraction File."

New: Silicon Powder Line Position Standard silicon-powder-line-position-standard

  • Created Silicon Powder Line Position Standard (part): "Calibrates the diffractometer's 2-theta scale, run alone or mixed into a sample, so the lattice parameters of a new phase can be trusted. Certified lattice parameter with a stated uncertainty, for SRM 640g a = 0.5431144 nm at 22.5 °C with an expanded uncertainty of 0.000008 nm."

New: Density Determination Kit density-determination-kit

  • Created Density Determination Kit (part): "Weighs a pellet in air and immersed in a liquid on the analytical balance, giving its Archimedes density to compare with the X-ray density. Must match the make and model series of the balance, which should read to 0.1 mg for pellets of about 1 g."

New: Structure and Composition superconductor-materials-lab-structure

  • Created Structure and Composition (assembly): "A benchtop powder X-ray diffractometer with analysis software, a reference database and a silicon standard identifies the crystalline phases in a fired or melted sample. A stereo microscope, a density kit and an optional electron microscope check its microstructure and density."
  • Added X-Ray Diffractometer × 1
  • Added zero-background-sample-holders × 4
  • Added phase-identification-and-rietveld-software × 1
  • Added reference-pattern-database × 1
  • Added silicon-powder-line-position-standard × 1
  • Added Stereo Microscope × 1
  • Added density-determination-kit × 1
  • Added Tabletop Electron Microscope × 1

New: Drying Oven drying-oven

  • Created Drying Oven (part): "Dries precursor powders before weighing, and dries glassware and pressed pellets, so absorbed water does not shift the stoichiometry. Gravity convection bench oven of about 20 to 65 L that reaches at least 200 °C, as powders do not need forced air."

New: Vacuum Desiccator vacuum-desiccator

  • Created Vacuum Desiccator (part): "Stores dried precursors, hygroscopic oxides and finished samples under vacuum or over desiccant so they take up no water or carbon dioxide. Chamber with a plate of about 190 to 250 mm that holds vacuum for 24 hours and has a stopcock for a pump line."

New: Indicating Desiccant indicating-desiccant

  • Created Indicating Desiccant (part): "Takes up water vapor inside the desiccators and changes color when it is spent and needs drying out in the oven. Indicating calcium sulfate of about 8 mesh or indicating silica gel, enough to cover the well of each desiccator."

New: Borosilicate Beakers borosilicate-beakers

  • Created Borosilicate Beakers (part): "Holds precursor solutions, rinse baths and powders during weighing, mixing and cleaning. Graduated low-form borosilicate beakers in sizes from 50 mL to 1 L."

New: Wash Bottles wash-bottles

  • Created Wash Bottles (part): "Dispenses deionized water, ethanol, isopropanol and acetone for rinsing mortars, dies and glassware. 500 mL LDPE squeeze bottle with a draw tube, one bottle per liquid and each labeled with its contents."

New: Lint-Free Wipes lint-free-wipes

  • Created Lint-Free Wipes (part): "Wipes mortars, dies, spatulas, tweezers and sample holders with solvent between batches without leaving fibers. Low-lint tissue wipers of about 110 x 210 mm in dispenser boxes."

New: Tweezers and Hand Tools tweezers-and-hand-tools

  • Created Tweezers and Hand Tools (part): "Handles pellets, wires, foils and small samples, and drives the fasteners used to assemble probes, dies and fixtures. Non-magnetic stainless steel tweezers in fine-point and flat-tip styles, plus a precision bit driver set."

New: Solder Wire solder-wire

  • Created Solder Wire (part): "Joins probe wiring, connectors and coil leads away from the sample's voltage path, because tin-lead solder superconducts below about 7 K. Flux-cored Sn63/Pb37 wire about 0.8 mm in diameter for joints that will be cooled, since tin-rich lead-free alloys can turn brittle at cryogenic temperatures."

New: Lab Notebook lab-notebook

  • Created Lab Notebook (part): "Records each batch's masses, firing schedule, sample identifier and measurement files so a result can be traced and repeated. Bound paper notebook with grid pages, or an electronic notebook that timestamps entries and exports to open file formats."

New: General Bench superconductor-materials-lab-bench

  • Created General Bench (assembly): "Heating, drying, cleaning and storage, with the hand tools and soldering gear for wiring samples. The drying oven and vacuum desiccators keep water out of the precursor powders, and the notebook and label printer keep each sample traceable."
  • Added Magnetic Stirrer × 1
  • Added drying-oven × 1
  • Added vacuum-desiccator × 2
  • Added indicating-desiccant × 2
  • Added Ultrasonic Cleaner × 1
  • Added Lab Water Purification System × 1
  • Added borosilicate-beakers × 2
  • Added wash-bottles × 6
  • Added lint-free-wipes × 1
  • Added tweezers-and-hand-tools × 1
  • Added Soldering Station × 1
  • Added solder-wire × 1
  • Added Digital Multimeter × 1
  • Added Handheld Label Maker × 1
  • Added lab-notebook × 3

New: Canopy Exhaust Hood canopy-exhaust-hood

  • Created Canopy Exhaust Hood (part): "Captures heat, metal oxide vapor and nitrogen oxides that rise from box and tube furnaces during firing and ducts them out of the room. Fiberglass or stainless steel canopy wider than the furnace it covers, ducted to an exhaust blower sized by the installer."

New: Oxygen Depletion Monitor oxygen-depletion-monitor

  • Created Oxygen Depletion Monitor (part): "Sounds an alarm when boil-off from liquid nitrogen or a leak of argon or nitrogen lowers the oxygen level in the room. Fixed wall unit with a first alarm at 19.5% oxygen, audible and visual alarms, a relay output and a stated sensor life, mounted near the dewar and cylinders."

New: Gas Cylinder Wall Bracket gas-cylinder-wall-bracket

  • Created Gas Cylinder Wall Bracket (part): "Holds each argon and oxygen cylinder upright against the wall so it cannot fall and break its valve. Steel bracket bolted to the wall structure with a strap or chain for cylinders 4 to 12 in in diameter, one position for every cylinder in use or in storage."

New: Flammable Liquids Safety Cabinet flammable-liquids-safety-cabinet

  • Created Flammable Liquids Safety Cabinet (part): "Stores the ethanol, isopropanol and acetone used for wet grinding and cleaning. Double-wall steel cabinet, FM approved and meeting NFPA 30 and OSHA rules, where 12 gallons of capacity covers a few liters of solvent."

New: Corrosives Cabinet corrosives-cabinet

  • Created Corrosives Cabinet (part): "Stores nitric, hydrochloric and other acids used for dissolving precursors and cleaning labware, apart from solvents and metal powders. Polyethylene body, or steel with polyethylene trays and sump liner, sized for the few bottles kept and with acids and bases on separate trays."

New: Class D Fire Extinguisher class-d-fire-extinguisher

  • Created Class D Fire Extinguisher (part): "Smothers burning magnesium, sodium, zirconium or titanium powder, and is needed only where reactive metals or metal powders are kept. 30 lb sodium chloride dry powder unit with a soft-flow applicator, with a copper powder agent used instead for lithium fires."

New: First Aid Kit first-aid-kit

  • Created First Aid Kit (part): "Treats cuts and minor burns until medical help is reached. Wall kit meeting ANSI Z308.1-2021 Class A, with burn dressings added for furnace and cryogen work."

New: Chemical Spill Kit chemical-spill-kit

  • Created Chemical Spill Kit (part): "Absorbs and contains a spilled acid, base or solvent and provides a bag or bucket for the used absorbent. Hazmat-grade pads and socks rated for acids, bases and unknown liquids, with capacity above the largest bottle kept and with acid and base neutralizer on hand."

New: Hazardous Waste Containers and Labels hazardous-waste-containers-and-labels

  • Created Hazardous Waste Containers and Labels (part): "Collects spent powders, contaminated wipes and waste acids or solvents in separate closed containers until a licensed hauler removes them. UN-rated HDPE pails or carboys with screw lids, one per waste stream, each carrying a hazardous waste label that names the contents and the start date."

New: Safety Glasses safety-glasses

  • Created Safety Glasses (part): "Protects the eyes from pellet fragments and flying powder during grinding, pressing and furnace loading. Impact-rated eyewear marked ANSI Z87.1+ with side coverage, one pair per person plus spares for visitors."

New: Chemical Splash Goggles chemical-splash-goggles

  • Created Chemical Splash Goggles (part): "Seals around the eyes against liquid splashes when acids, bases and solvents are poured, diluted or used to dissolve precursors. Indirect-vent goggles marked ANSI Z87.1+ with the D3 droplet and splash rating, in a style that fits over prescription glasses where needed."

New: Lab Coat lab-coat

  • Created Lab Coat (part): "Keeps powder and splashes off street clothes so that toxic dust stays in the lab. Knee length with long sleeves, in cotton blend for general work or flame-resistant fabric for work at the furnace and with flammable solvents."

New: Nitrile Gloves nitrile-gloves

  • Created Nitrile Gloves (part): "Keeps toxic precursor powders and solvents off the skin, and skin oils off the samples, during weighing, grinding and pellet handling. Powder-free nitrile, 4 to 6 mil, in each wearer's size, changed after contact with lead, thallium or barium compounds."

New: Chemical-Resistant Gauntlet Gloves chemical-resistant-gauntlet-gloves

  • Created Chemical-Resistant Gauntlet Gloves (part): "Protects the hands and forearms when concentrated acids are poured or labware is cleaned in acid. Reusable neoprene or butyl gloves 12 in or longer and about 15 mil thick, checked against the seller's chemical resistance chart for nitric and hydrochloric acid."

New: Half-Mask Respirator with P100 Filters half-mask-respirator-with-p100-filters

  • Created Half-Mask Respirator with P100 Filters (part): "Backs up the fume hood when fine oxide powders are handled outside it, for example during spill cleanup, furnace cleaning or die loading. NIOSH-approved elastomeric half facepiece in the wearer's size with a pair of P100 particulate filters, fit tested for each user."

New: Heat-Resistant Gloves heat-resistant-gloves

  • Created Heat-Resistant Gloves (part): "Protects hands from radiant heat and brief contact when crucibles, boats and tubes are moved in and out of a hot furnace with tongs. Aramid or felt-insulated gloves 13 in or longer with a stated contact heat rating, used with tongs because furnace ware can come out hotter than the glove rating."

New: Cryogenic Gloves, Apron and Face Shield cryogenic-gloves-apron-and-face-shield

  • Created Cryogenic Gloves, Apron and Face Shield (part): "Protects hands, body and face from splashes and cold surfaces when liquid nitrogen is poured and samples are lowered into it. Insulated gloves and apron rated for splash and contact down to -196 °C but not for immersion, with a full face shield worn over safety glasses."

New: Safety and Room superconductor-materials-lab-safety

  • Created Safety and Room (assembly): "Hoods remove toxic dust, acid fumes and furnace off-gas, and eye, hand and body protection covers chemical, furnace and liquid nitrogen work. An oxygen monitor, cylinder brackets and storage cabinets guard the room, and the eyewash, extinguishers, spill kit and waste containers cover accidents and disposal."
  • Added Fume Hood × 1
  • Added canopy-exhaust-hood × 1
  • Added Laboratory Glovebox × 1
  • Added oxygen-depletion-monitor × 1
  • Added gas-cylinder-wall-bracket × 3
  • Added flammable-liquids-safety-cabinet × 1
  • Added corrosives-cabinet × 1
  • Added Combination Safety Shower & Eyewash × 1
  • Added Fire Extinguisher × 2
  • Added class-d-fire-extinguisher × 1
  • Added first-aid-kit × 1
  • Added chemical-spill-kit × 1
  • Added hazardous-waste-containers-and-labels × 1
  • Added safety-glasses × 6
  • Added chemical-splash-goggles × 4
  • Added lab-coat × 4
  • Added nitrile-gloves × 4
  • Added chemical-resistant-gauntlet-gloves × 2
  • Added half-mask-respirator-with-p100-filters × 3
  • Added heat-resistant-gloves × 2
  • Added cryogenic-gloves-apron-and-face-shield × 1
  • Added Laboratory Bench × 2
  • Added UPS Battery Backup × 1

New: Yttrium Oxide Powder yttrium-oxide-powder

  • Created Yttrium Oxide Powder (part): "Supplies the yttrium for YBa2Cu3O7, the standard test compound, fired from Y2O3, BaCO3 and CuO in a 1:4:6 molar ratio. Buy 99.99% on a rare earth oxide basis as a fine powder, of which 100 g makes more than 500 g of YBa2Cu3O7."

New: Barium Carbonate Powder barium-carbonate-powder

  • Created Barium Carbonate Powder (part): "Supplies the barium for YBa2Cu3O7 and releases CO2 as it decomposes during calcination. Buy 99.9% or better on a metals basis and allow about 0.6 g per gram of YBa2Cu3O7, the largest share of any precursor by mass."

New: Copper(II) Oxide Powder copper-ii-oxide-powder

  • Created Copper(II) Oxide Powder (part): "Supplies the copper for YBa2Cu3O7 and for the bismuth cuprates. Buy 99.9% or better on a metals basis with low iron, nickel and zinc on the certificate, because they substitute on the copper site and lower Tc."

New: Bismuth(III) Oxide Powder bismuth-iii-oxide-powder

  • Created Bismuth(III) Oxide Powder (part): "Supplies the bismuth for Bi2Sr2CaCu2O8 (Bi-2212) and Bi2Sr2Ca2Cu3O10 (Bi-2223). Buy 99.9% or better on a metals basis and run the first calcination below its melting point near 817 °C."

New: Strontium Carbonate Powder strontium-carbonate-powder

  • Created Strontium Carbonate Powder (part): "Supplies the strontium for the bismuth cuprates Bi-2212 and Bi-2223. Buy 99.9% or better on a metals basis with barium and calcium stated on the certificate, because strontium salts carry both."

New: Calcium Carbonate Powder calcium-carbonate-powder

  • Created Calcium Carbonate Powder (part): "Supplies the calcium for the bismuth cuprates Bi-2212 and Bi-2223. Buy 99.95% or better on a metals basis."

New: Lead(II) Oxide Powder lead-ii-oxide-powder

  • Created Lead(II) Oxide Powder (part): "Replaces about 10 to 20% of the bismuth to speed formation of the 110 K Bi-2223 phase. Buy 99.9% or better in a 50 g pack, which covers many batches because each one uses little."

New: Magnesium and Boron Powders magnesium-and-boron-powders

  • Created Magnesium and Boron Powders (part): "Supplies the elements for MgB2 (Tc 39 K), reacted at about 650 to 900 °C in argon or a sealed metal tube because magnesium vapor attacks bare quartz. Buy magnesium of 99.8% at -325 mesh and amorphous boron of 95% or better at micron size or finer, because boron purity and particle size limit MgB2 quality."

New: Weighing Boats weighing-boats

  • Created Weighing Boats (part): "Holds precursor powders on the balance and during transfer to the mortar. Choose antistatic polystyrene of 20 to 100 mL, because fine oxide powders cling to untreated plastic."

New: Solvents (Ethanol, Isopropanol, Acetone) solvents-ethanol-isopropanol-acetone

  • Created Solvents (Ethanol, Isopropanol, Acetone) (part): "Wets precursor powders for grinding and mixing (ethanol or isopropanol) and cleans dies, mortars and sample surfaces (acetone, isopropanol). Buy ACS reagent grade at 99.5% or better, which limits water to 0.5% in acetone and 0.2% in isopropanol, and denatured 200 proof ethanol for grinding."

New: Oxygen and Argon Cylinders oxygen-and-argon-cylinders

  • Created Oxygen and Argon Cylinders (part): "Supplies oxygen for the anneal that sets the oxygen content of YBa2Cu3O7 and argon for arc melting, intermetallic firing and purging. Order argon at 99.999% and oxygen at 99.5% or better in rented cylinders of about 300 cubic feet, with a CGA 580 regulator for argon and CGA 540 for oxygen."

New: Liquid Nitrogen liquid-nitrogen

  • Created Liquid Nitrogen (part): "Cools samples to 77 K for resistance measurements and the levitation check, and precools the cryostat. Order a rented low-pressure (about 22 psi) liquid cylinder of about 180 L or collect it in a dewar, on a schedule because the cylinder loses liquid to boil-off."

New: YBCO Levitation Disk with Magnet ybco-levitation-disk-with-magnet

  • Created YBCO Levitation Disk with Magnet (part): "Provides a known 90 K superconductor to confirm that the levitation check and the susceptibility coil respond before a new sample is tested. A sintered YBa2Cu3O7 disk about 20 mm across with a small NdFeB magnet shows the Meissner effect, and only strong flux-pinned levitation needs a melt-textured disk."

New: High-Temperature Superconductor Bar or Tape high-temperature-superconductor-bar-or-tape

  • Created High-Temperature Superconductor Bar or Tape (part): "Provides a known transition (Bi-2223 near 108 to 110 K, REBCO near 90 K) for validating four-probe resistance against temperature. Choose a bar or tape with solderable silver ends and a stated Tc, and ask REBCO makers for a short length without copper stabilizer, which masks resistance above Tc."

New: Niobium Foil niobium-foil

  • Created Niobium Foil (part): "Checks the cold end of the resistance and susceptibility setups with its 9.2 K transition and supplies niobium for arc-melted intermetallics. Buy 99.8% or better, annealed, 0.1 to 0.25 mm thick so that strips can be cut with scissors."

New: Lead, Tin and Indium Metal lead-tin-and-indium-metal

  • Created Lead, Tin and Indium Metal (part): "Checks thermometry at the 7.2 K transition of lead, and supplies tin for Nb3Sn and indium for pressed contact pads. Buy 99.99% or better as shot for melting and 1 mm wire for contacts, and note that tin (3.7 K) and indium (3.4 K) transitions need a stage that cold."

New: Sample Vials, Sealing Film and Labels sample-vials-sealing-film-and-labels

  • Created Sample Vials, Sealing Film and Labels (part): "Stores pellets, powders and offcuts between firings and measurements, sealed against humidity and labeled with composition and date. Choose glass vials of 5 to 30 mL with PTFE-lined caps, laboratory sealing film 4 inches wide and moisture-resistant labels."

New: Chemicals, Gases and Reference Samples superconductor-materials-lab-stock

  • Created Chemicals, Gases and Reference Samples (assembly): "Oxide and carbonate powders are the precursors for YBa2Cu3O7 and the bismuth cuprates, with magnesium and boron for MgB2. Oxygen and argon supply the furnace and arc-melting atmospheres, liquid nitrogen cools samples, and known superconductors (a YBCO disk, a Bi-2223 bar, niobium, lead) check the measurement setups."
  • Added yttrium-oxide-powder × 1
  • Added barium-carbonate-powder × 1
  • Added copper-ii-oxide-powder × 2
  • Added bismuth-iii-oxide-powder × 1
  • Added strontium-carbonate-powder × 1
  • Added calcium-carbonate-powder × 1
  • Added lead-ii-oxide-powder × 1
  • Added magnesium-and-boron-powders × 1
  • Added weighing-boats × 1
  • Added solvents-ethanol-isopropanol-acetone × 3
  • Added oxygen-and-argon-cylinders × 2
  • Added liquid-nitrogen × 1
  • Added ybco-levitation-disk-with-magnet × 1
  • Added high-temperature-superconductor-bar-or-tape × 1
  • Added niobium-foil × 1
  • Added lead-tin-and-indium-metal × 1
  • Added sample-vials-sealing-film-and-labels × 1

New: Superconductor Materials Lab superconductor-materials-lab

  • Created Superconductor Materials Lab (product): "A small laboratory for making bulk samples of candidate superconductors and testing them: powder preparation, furnaces, cryogenic resistance and susceptibility measurement, X-ray diffraction, safety equipment and stock, 115 items in seven groups."
  • Added superconductor-materials-lab-powder × 1
  • Added superconductor-materials-lab-furnace × 1
  • Added superconductor-materials-lab-measurement × 1
  • Added superconductor-materials-lab-structure × 1
  • Added superconductor-materials-lab-bench × 1
  • Added superconductor-materials-lab-safety × 1
  • Added superconductor-materials-lab-stock × 1

Machine findings

  • Safety and Room: 23 direct children (dominant function: Display information), worth checking for integration or standardization
  • Furnaces, Gas and Vacuum: 18 direct children (dominant function: Convert energy), worth checking for integration or standardization
  • Cryogenics and Measurement: 18 direct children (dominant function: Sense or measure), worth checking for integration or standardization
  • Chemicals, Gases and Reference Samples: 17 direct children (dominant function: Communicate signal), worth checking for integration or standardization
  • Powder Preparation and Shaping: 16 direct children (dominant function: Process material), worth checking for integration or standardization
  • General Bench: 15 direct children (dominant function: Display information), worth checking for integration or standardization
  • Superconductor Materials Lab functions after this change: Filter or clean, Convert energy, Connect electrically