BOMwiki the bill-of-materials encyclopedia
30,454,201 parts mapped · 193,225 items

You are viewing r80937 of this page, not the current version. Go to current · history

Heat-Pump Water Heater

Product

Overview

A heat-pump water heater warms domestic hot water by moving heat rather than generating it directly. Instead of converting electricity straight into heat with a resistance coil, it runs a refrigeration cycle backward: it extracts low-grade heat from the surrounding room air and pumps it into the water tank. Because it relocates existing heat, it delivers roughly three to four units of heat for every unit of electricity, making it two to four times more efficient than a standard electric tank heater. A resistance element remains as backup for cold rooms or heavy demand, which is why these units are sold as "hybrid" heaters.

Water is stored in the Storage Tank, a glass-lined steel vessel protected by an Anode Rod. The Heat-Pump Module carries the refrigerant circuit, the Backup Heater adds an electric element with a Thermal Fuse, and the Condensate Pan catches the water wrung out of the air. The Control Module runs everything and the T&P Relief Valve protects against overpressure.

How it works

The heart of the unit is the vapor-compression loop. The Air Fan draws room air across the cold Evaporator Coil, where liquid refrigerant boils and soaks up heat. The Compressor then squeezes that vapor, raising its temperature well above the tank water. The hot gas flows through the Condenser Coil wrapped around the tank, giving up its heat to the water and condensing back to liquid. The Expansion Valve drops the pressure and the cycle repeats, with the Refrigerant Charge carrying heat each pass.

The Control Module reads the Sensor Set and chooses how to heat: heat-pump only for efficiency, the Heating Element for fast recovery, or a hybrid blend. As warm room air gives up heat at the evaporator it also cools and dehumidifies, so moisture condenses and drains through the Condensate Pan. A by-product is cool, drier exhaust air, useful in a utility room but a reason these heaters belong in conditioned or semi-conditioned spaces with enough air volume.

Bill of materials for Heat-Pump Water Heater

9 top-level lines as of r80937
# Item / sub-assembly Part no. Qty/assy Ext. qty Parts Type
1 Storage Tank 5 parts heat-pump-water-heater-tank 1× 1 0 assembly
2 Heat-Pump Module 6 parts heat-pump-water-heater-hp-module 1× 1 0 assembly
3 Backup Heater 3 parts heat-pump-water-heater-backup 1× 1 0 assembly
4 Condensate Pan 2 parts heat-pump-water-heater-condensate-pan 1× 1 0 assembly
5 Control Module 8 parts heat-pump-water-heater-control 1× 1 0 assembly
6 Sensor Set 2 parts heat-pump-water-heater-sensors 1× 1 0 assembly
7 T&P Relief Valve 3 parts heat-pump-water-heater-tp-valve 1× 1 0 assembly
8 O-Ring Set oring-set 1× 1 · part
9 Fastener Set fastener-set 1× 1 · part

388-word article