Server Rack
ProductOverview
A server rack is the standardized steel enclosure that mounts, powers, cools and secures data-center equipment. This is a 42U cabinet built to the EIA-310 19-inch standard, so any compliant server, switch or storage unit bolts into its rails. Beyond structure, it integrates the supporting systems a rack of running hardware needs: power, airflow, cabling and monitoring.
The load-bearing core is the Rack Frame, a welded steel structure with four adjustable mounting rails, casters and leveling feet. Perforated Front Door and Rear Door panels and removable Side Panel sides enclose it. Power comes from dual Rack PDU (Metered/Switched) strips, heat is pulled out by the Rear-Door Fan Unit, and cabling is dressed through the Cable Management managers. A KVM Console Drawer gives local console access, while a Environmental Sensor Kit reports conditions remotely and a Grounding & Bonding Kit bonds every metal part to earth.
How it works
Mounted equipment draws front-to-back airflow: cold supply air enters through the ~70%-open front door, passes through the servers, and exits the rear. Blanking Panel panels seal unused U-spaces and Airflow Baffle containment stops hot exhaust from recirculating to the intakes, keeping inlet temperatures within spec. The rear-door fan array adds active extraction for dense, high-wattage loads. Each metered/switched PDU distributes utility power to outlets, measures current per circuit, and can switch individual outlets remotely for staged power-up or hung-server reboots. The grounding system bonds the frame, doors and rails so any fault current returns safely to earth and equipment shares a common reference, while the sensor kit logs temperature, humidity and door-open events to the building management system.
Server Rack parts and their functions
14 top-level parts · 304 parts in total · full bill of materials below| # | Part | Qty | What it does |
|---|---|---|---|
| 1 | Rack Frame 7 parts | 1× | Welded/bolted steel frame + rails |
| 2 | Front Door 4 parts | 1× | Perforated front door |
| 3 | Rear Door 4 parts | 1× | Perforated rear door |
| 4 | Side Panel 2 parts | 2× | Left + right removable sides |
| 5 | Cable Management 4 parts | 1× | Vertical + horizontal managers |
| 6 | Rack PDU (Metered/Switched) 6 parts | 2× | Dual metered/switched PDUs |
| 7 | Rear-Door Fan Unit 4 parts | 1× | Rear-door fan unit |
| 8 | KVM Console Drawer 4 parts | 1× | Console drawer |
| 9 | Blanking Panel | 12× | 1U/2U airflow blanking |
| 10 | Equipment Shelf | 2× | Fixed equipment shelves |
| 11 | Airflow Baffle | 4× | Containment baffles |
| 12 | Grounding & Bonding Kit 3 parts | 1× | Bonding/grounding kit |
| 13 | Environmental Sensor Kit 3 parts | 1× | Environmental + door sensors |
| 14 | Power Whip | 1× | L6-30 power whip / cabling |
3D model
No 3D model yet. Have a CAD file of this? Add a 3D model. STL renders right on this page; STEP, FreeCAD, and OpenSCAD sources are welcome too (openly licensed, like all 3D models on BOMwiki).
Build & assembly graph
expand / collapse · shared sub-assemblies converge · links to related products · est. labourTap an assembly to expand/collapse · tap a part to open it · use “Open page” for any node · drag to pan, scroll to zoom.
Bill of materials for Server Rack
14 top-level lines · 67 rows shown · 304 parts total · indented to 3 levels| # | Item / sub-assembly | Part no. | Qty/assy | Ext. qty | Parts | Type |
|---|---|---|---|---|---|---|
| 1 | Rack Frame 7 parts | server-rack-frame | 1× | 1 | 95 | assembly |
| 1.1 | Welded Steel Frame | server-rack-weld-frame | 1× | 1 | · | part |
| 1.2 | 19-inch Mounting Rail | server-rack-mounting-rail | 4× | 4 | · | part |
| 1.3 | Cage Nut | server-rack-cage-nut | 80× | 80 | · | part |
| 1.4 | Top Panel | server-rack-top-panel | 1× | 1 | · | part |
| 1.5 | Swivel Caster | server-rack-caster | 4× | 4 | · | part |
| 1.6 | Leveling Foot | server-rack-leveling-foot | 4× | 4 | · | part |
| 1.7 | Fastener Set | fastener-set | 1× | 1 | · | part |
| 2 | Front Door 4 parts | server-rack-front-door | 1× | 1 | 5 | assembly |
| 2.1 | Perforated Door Panel | server-rack-perf-door-panel | 1× | 1 | · | part |
| 2.2 | Door Hinge | server-rack-door-hinge | 2× | 2 | · | part |
| 2.3 | Locking Swing Handle | server-rack-door-handle | 1× | 1 | · | part |
| 2.4 | Fastener Set | fastener-set | 1× | 1 | · | part |
| 3 | Rear Door 4 parts | server-rack-rear-door | 1× | 1 | 5 | assembly |
| 3.1 | Perforated Door Panel | server-rack-perf-door-panel | 1× | 1 | · | part |
| 3.2 | Door Hinge | server-rack-door-hinge | 2× | 2 | · | part |
| 3.3 | Locking Swing Handle | server-rack-door-handle | 1× | 1 | · | part |
| 3.4 | Fastener Set | fastener-set | 1× | 1 | · | part |
| 4 | Side Panel 2 parts | server-rack-side-panel | 2× | 2 | 2 | assembly |
| 4.1 | Sheet Metal Panel | sheet-panel | 1× | 2 | · | part |
| 4.2 | Fastener Set | fastener-set | 1× | 2 | · | part |
| 5 | Cable Management 4 parts | server-rack-cable-mgmt | 1× | 1 | 12 | assembly |
| 5.1 | Vertical Cable Manager | server-rack-vertical-manager | 2× | 2 | · | part |
| 5.2 | Horizontal Cable Manager | server-rack-horizontal-manager | 4× | 4 | · | part |
| 5.3 | Brush Grommet | server-rack-brush-grommet | 4× | 4 | · | part |
| 5.4 | Cable Tray | server-rack-cable-tray | 2× | 2 | · | part |
| 6 | Rack PDU (Metered/Switched) 6 parts | server-rack-pdu | 2× | 2 | 57 | assembly |
| 6.1 | PDU Chassis | server-rack-pdu-chassis | 1× | 2 | · | part |
| 6.2 | PDU Outlet (IEC) | server-rack-pdu-outlet | 42× | 84 | · | part |
| 6.3 | PDU Branch Breaker | server-rack-pdu-breaker | 2× | 4 | · | part |
| 6.4 | PDU Metering Board 3 parts | server-rack-pdu-metering-board | 1× | 2 | 10 | assembly |
| 6.4.1 | Bare PCB | pcb-bare | 1× | 2 | · | part |
| 6.4.2 | Microcontroller | mcu | 1× | 2 | · | part |
| 6.4.3 | Connector | connector | 8× | 16 | · | part |
| 6.5 | LCD Panel | lcd-panel | 1× | 2 | · | part |
| 6.6 | Management Network Port | server-rack-pdu-network-port | 1× | 2 | · | part |
| 7 | Rear-Door Fan Unit 4 parts | server-rack-cooling-unit | 1× | 1 | 16 | assembly |
| 7.1 | Blower Motor | blower-motor | 6× | 6 | · | part |
| 7.2 | Fan Controller 3 parts | server-rack-fan-controller | 1× | 1 | 8 | assembly |
| 7.2.1 | Bare PCB | pcb-bare | 1× | 1 | · | part |
| 7.2.2 | Microcontroller | mcu | 1× | 1 | · | part |
| 7.2.3 | Connector | connector | 6× | 6 | · | part |
| 7.3 | Power Supply | power-supply | 1× | 1 | · | part |
| 7.4 | Wire Bundle | wire-bundle | 1× | 1 | · | part |
| 8 | KVM Console Drawer 4 parts | server-rack-kvm-drawer | 1× | 1 | 13 | assembly |
| 8.1 | LCD Panel | lcd-panel | 1× | 1 | · | part |
| 8.2 | Console Keyboard | server-rack-kvm-keyboard | 1× | 1 | · | part |
| 8.3 | KVM Switch Board 3 parts | server-rack-kvm-switch | 1× | 1 | 10 | assembly |
| 8.3.1 | Bare PCB | pcb-bare | 1× | 1 | · | part |
| 8.3.2 | Microcontroller | mcu | 1× | 1 | · | part |
| 8.3.3 | Connector | connector | 8× | 8 | · | part |
| 8.4 | Fastener Set | fastener-set | 1× | 1 | · | part |
| 9 | Blanking Panel | server-rack-blanking-panel | 12× | 12 | · | part |
| 10 | Equipment Shelf | server-rack-shelf | 2× | 2 | · | part |
| 11 | Airflow Baffle | server-rack-airflow-baffle | 4× | 4 | · | part |
| 12 | Grounding & Bonding Kit 3 parts | server-rack-grounding-kit | 1× | 1 | 8 | assembly |
| 12.1 | Ground Bus Bar | server-rack-ground-bar | 1× | 1 | · | part |
| 12.2 | Bonding Jumper | server-rack-bonding-jumper | 6× | 6 | · | part |
| 12.3 | Fastener Set | fastener-set | 1× | 1 | · | part |
| 13 | Environmental Sensor Kit 3 parts | server-rack-sensor-kit | 1× | 1 | 13 | assembly |
| 13.1 | Temp/Humidity Sensor | server-rack-temp-humidity-sensor | 3× | 3 | · | part |
| 13.2 | Door Contact Sensor | server-rack-door-sensor | 2× | 2 | · | part |
| 13.3 | Sensor Gateway Board 3 parts | server-rack-sensor-gateway | 1× | 1 | 8 | assembly |
| 13.3.1 | Bare PCB | pcb-bare | 1× | 1 | · | part |
| 13.3.2 | Microcontroller | mcu | 1× | 1 | · | part |
| 13.3.3 | Connector | connector | 6× | 6 | · | part |
| 14 | Power Whip | server-rack-power-whip | 1× | 1 | · | part |
Something wrong in this list? Report a problem with this BOM.
Sourcing: possible vendors
Browse the supplier directory → Prices, MOQ, and lead times are algorithmic estimates, not quotes, and not claims about these companies. Company mappings are curated by keyword; est. price band $30–$50k. How estimates work| Vendor | HQ | Specialty | MOQ | Lead time |
|---|---|---|---|---|
|
🇺🇸Cisco
cisco.com ↗
|
San Jose, US | Networking | 500 units | 8–14 wks |
|
🇺🇸Juniper
juniper.net ↗
|
Sunnyvale, US | Networking | 500 units | 8–14 wks |
| arista.com ↗ | Santa Clara, US | Networking | 500 units | 8–14 wks |
|
🇫🇮Nokia
nokia.com ↗
|
Espoo, FI | Telecom equipment | 500 units | 8–14 wks |
|
🇨🇳Huawei
huawei.com ↗
|
Shenzhen, CN | Networking & telecom | 500 units | 8–14 wks |
297-word article