Control & Safety System
AssemblyPLC that sequences startup, modulates current, and enforces a hardwired safety chain around gas hazards. A full specification article for this item is being written. Meanwhile its bill of materials and connections are below.
Bill of materials for Control & Safety System
8 top-level lines as of r86723| # | Item / sub-assembly | Part no. | Qty/assy | Ext. qty | Parts | Type |
|---|---|---|---|---|---|---|
| 1 | Bare PCB | pcb-bare | 1× | 1 | · | part |
| 2 | Microcontroller | mcu | 1× | 1 | · | part |
| 3 | SMD Passive (R/C/L) | smd-passives | 1× | 1 | · | part |
| 4 | H2 Leak Sensor | hydrogen-electrolyzer-h2-leak-sensor | 2× | 2 | · | part |
| 5 | Cell Voltage Monitor | hydrogen-electrolyzer-cell-voltage-monitor | 1× | 1 | · | part |
| 6 | Relay | relay | 4× | 4 | · | part |
| 7 | LCD Panel | lcd-panel | 1× | 1 | · | part |
| 8 | Connector | connector | 6× | 6 | · | part |