BS&W Monitor and Diverter
AssemblyMeasures basic sediment and water by capacitance; if water exceeds the contract limit it diverts the stream back to the tank rather than to sale. A full specification article for this item is being written. Meanwhile its bill of materials and connections are below.
Bill of materials for BS&W Monitor and Diverter
4 top-level lines as of r94775| # | Item / sub-assembly | Part no. | Qty/assy | Ext. qty | Parts | Type |
|---|---|---|---|---|---|---|
| 1 | Capacitance BS&W Probe | lact-bsw-probe | 1× | 1 | · | part |
| 2 | BS&W Analyzer Electronics 4 parts | lact-bsw-analyzer | 1× | 1 | 0 | assembly |
| 3 | Reject Diverter Valve 3 parts | lact-divert-valve | 1× | 1 | 0 | assembly |
| 4 | O-Ring Set | oring-set | 1× | 1 | · | part |